New Yorker Boiler Problems [9 Easy Solutions]

Struggling with your New Yorker boiler problems is certainly painful. This is why we are here to make things easy for you. In this article, you will get to know about the 9 most common New Yorker boiler troubleshooting.

We have taken all the broiler problems from the users’ experience as well as from the New Yorker boiler manuals and given the ultimate solution by our expert. So, we can assure you that you are going to fix your broiler issues effortlessly.   

9 New Yorker Boiler Problems and Their Solutions

The common New York Broiler problems are temperature sensor failure, communication failure, broiler not turning on, no burner output, blown fuse, switching off, noises, no spark, and faulty pilot. So, read the whole article. You will know all about the problems and their easy solutions.  

Pro Tip: Knowing about these solutions will allow you to solve Munchkin Boiler problems also. 

1: Temperature Sensor Failure

Temperature sensor failure is a typical New Yorker boiler problem. A temperature sensor is an essential component of boilers. It determines the temperature of water in the boiler. 

Faulty wiring or short connection can lead to temperature sensor failure. There is no way to know about the condition of the water if this happens. 

Solution:

This problem of the New Yorker boiler is easily detectable. The boiler will just stop showing the temperature. As the root of this problem lies in the wiring, you have to work on that first. Here’s what to do:

  • Check the sensor wire. Replace it if damaged
  • Check if the sensor is perfectly connected to the central control
  • Replace the sensor if the wirings are okay
  • Replace the whole control if the problem persists with the new sensor

2: Communication Failure

Communication failure is probably the most problematic thing you can face with your New Yorker boiler. The display board of your boiler is connected to the mainboard. 

This connection allows you to know about your boiler condition through the screen of the display board. If the connection between this display board and the main board fails, you won’t get any information about your device. 

Solution:

In this situation, the first thing you will have to do is check the wiring to EnviraCOM terminals. The wiring in these parts may have gotten loose. 

Fix the EnviraCOM terminals wiring. If the problem persists, you will have to consult an expert. 

3: Boiler Not Turning On

There can be many reasons why a New Yorker boiler won’t turn on. The causes behind this issue are related to the supply of power and resources. All of these reasons are pretty simple to deal with.

Solution:

Just make sure to get the following things right, and this should bring your boiler back to life.

  • Set the thermostat to heat
  • Fix the boiler circuit breaker if damaged
  • Keep the boiler gas valve open
  • Clean the boiler properly
  • Check and make sure all the wirings are okay

4: No Burner Output

The New Yorker boiler not firing up is a noteworthy issue. This problem is different from the New York boiler not turning on. 

In case of no burner output, the device turns on, and everything functions properly except for a burner. As a result, it fails to perform its task.

Solution:

If you are faced with this problem, then do not worry. Follow these points to fix the issue:

  • Make sure that the boiler is getting sufficient electrical and gas supply
  • Turn off the radiator and turn the radiator key to push out the trapped air
  • Pressurize the boiler if the pressure is too low
  • If nothing works, then replace the boiler

5: Blown Fuse

A surge of power can cause your boiler fuse to blow up. Your boiler won’t even start if there is no power supply. Check the fuse if it’s blown. If you find it in perfect condition, then the fault may be in the fuse wiring.

Solution:

Replace the fuse if you have any problem with it. Here’s how to do it simply:

  • Turn off the power supply
  • Locate the faulty fuse
  • Get a similar fuse 
  • Unscrew and dislocate the faulty fuse
  • Attach the new fuse

Now turn on the boiler. Call a professional if the fuse blows again.

6: Boiler Switching Off

New York boiler switching off is a common complaint of old users. Imbalance of boiler pressure or clogged pipes can be the reason behind this problem. 

Solution:

This problem can get severe, so as soon as your boiler starts to switch off automatically, try doing the following,

  • Turn off the boiler and clean it thoroughly 
  • Check if the thermostat is okay
  • Get a professional for pressure management of the boiler
  • Check if the power supply is providing consistent electricity

7: Boiler Noises

New Yorker boilers can make irritating noises from whistling, and buzzing to even banging. These noises usually result from faulty internal pipework, obstructions in pipes, and loose parts. No matter what the reason may be, no such noise is a good sign.

Solution:

Here’s what to do in case the New Yorker boiler makes noises,

  • Flush all the obstructions and sludges from the pipes
  • Increase the air pressure and the flame rate
  • Tighten up every screw in the boiler

Your boiler shouldn’t make any more noise if you get these points perfectly covered.

8: No Spark

New Yorker boiler deploys showing STA 6 can be followed by sparking noises. This can indicate a short circuit within the boiler system. Such problems gradually lead to bigger issues. So do not wait before taking adequate measures.

Solution:

Here’s what to do in case of sparkings,

  • Check for loose connections in the wiring
  • See if the ignition system is in perfect condition
  • Tighten up the loose ground connection
  • Fix the pilot spark gap

9: Faulty Pilot Light

Pilot lights are indicators of the activities of a boiler. It is a critical part of the whole device. However, the New Yorker boiler’s pilot light can sometimes mislead you due to its internal faults. Not fixing the pilot light will cause of your device not igniting and thus bring more problems. So deal with it as soon as possible.

Solution:

Complete the following instructions:

  • Make sure that the gas, air, and electrical supply is smooth
  • Ensure that there is no clogging or blockage within any pipes
  • Clean all the components regularly
  • Fix the cracked pilot electrode porcelain
  • Check if the control panel is okay

And that’s it. These were the most common New Yorker boiler problems the users face.

FAQ:

How Long Do New Yorker Boilers Last?

With proper care, a New Yorker boiler will easily last up to 30 years.

How Do You Diagnose A Boiler Problem?

Diagnosing a boiler problem is fairly simple. Just identify the part that is the root of the problem, then fix that component. Replace the parts that are beyond fixing.

Why do I only get hot water when the heating is on?

The reason behind this is a faulty diverter valve. Replacing or fixing the valve will solve the issue. 

Can you Repressurise a boiler when it’s on?

It is better to turn the boiler off while repressurizing.

How often should you have to Repressurise a boiler?

You should repressurize a boiler at least once a year.

To Conclude:

New Yorker boiler problems are not very hard to deal with. All you have to do is know certain details about your boiler. And this article has pretty much covered it all.

If you can utilize the points covered in this article, you won’t have any problem with your New Yorker boiler again.

Leave a comment below if you have any inquiries or problems.

About William

William is the founder of Fireplacehubs.com. He has real life practical skills in fixing smoker & heating appliance issues. He loves to share his knowledge & helps others in fixing their appliances & saving their money. William firmly believes that anyone can repair his or her unit with the correct guidance & knowledge. See more at about us.

3 thoughts on “New Yorker Boiler Problems [9 Easy Solutions]”

  1. There was a problem with the boiler in New Yorker. I was looking for a way to solve the problem. I did a search on the net to find out what caused this problem. I got the most beautiful and useful information and I got the exact information about the cause and solution of my New Yorker problem from here.